Fluke DP120 电压探针-【Fluke】福禄克 |
|
|
The DP120 differential voltage probe is designed to make measurements on signals with floating reference. The DP120 has two probes with shrouded banana probe tips 【one red, one black) and shielded cable for improved noise immunity. Input impedance between each input to shielding BNC is 5 MΩ in parallel with 6 pF. Input impedance between the inputs is 10 MΩ with a capacitance of 5 pF. Input: Probes with shrouded banana probe tip Probe length: 1.5 meter 【60 inch) Maximum Input Voltage to Ground: 600V rms CAT III per IEC 1010-2-031 / 1000Vrms CAT II, per IEC 1010-2-031 Maximum Differential Voltage: 1000V DC or1000Vrms or 1200V 【DC + ACpeak) Output Cable: Safety designed 0.5m 【5ft) BNC Cable Attenuation: 200x and 20x Bandwidth: DC to 20 MHz 【-3 dB) Accuracy: ±2.5% Rise time: 17.5 ns CMRR: 200x: @ 60 Hz = 80dB, @ 1 MHz = 50 dB 20x: @ 60 Hz = 70dB, @ 1 MHz = 40 dB Battery type: Alkaline 9 volt, NEDA, IEC6LR61 Battery life: 8-hour operation, 400-hour stand by Power Adapter: PM 8907/80n 【optional) Included Accessories: AC85A Large Jaw Alligator Clips and AC83 Pin-Grabber Test Clips
深圳市捌零零贸易有限公司为你提供最好的质量和服务! 订购电话:13480114737李桂乐QQ361904153
|